ASAP Aviation Procurement is pleased to announce that part number 43829-1 of NSN 5950-01-331-3922 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number 43829-1 is a Transformer Power manufactured by Coast Advanced Chip Magnetics Inc under CAGE Code 22558. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote. In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-331-3922 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013313922 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| C15300 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABKW | OVERALL HEIGHT | 2.270 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 3.850 INCHES MAXIMUM |
| ABTB | MOUNTING HOLE DIAMETER | 0.181 INCHES MINIMUM SINGLE GROUP AND 0.201 INCHES MAXIMUM SINGLE GROUP |
| AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
| CRBZ | WINDING OPERATING CURRENT | 1.75 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 16.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 7.42 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 14.85 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 10 TAB,SOLDER LUG |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| ABHP | OVERALL LENGTH | 4.560 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 66.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| CWJS | WINDING OPERATING VOLTAGE | 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| TEST | TEST DATA DOCUMENT | 13973-841355 DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 9.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
![]() |