ASAP Aviation Procurement is pleased to announce that part number DT2747 of NSN 5950-01-345-5596 is now available and in stock. We can get you one of the fastest and most competitive quotes on this part. Part number DT2747 is a Transformer Power manufactured by Glen Magnetics Inc under CAGE Code 62317. Simply fill out the Request for Quote (RFQ) form provided here to get started on your quote. In order to make sure that we get you your quote in a timely manner, please take the time to make sure that all fields are completely filled out, particularly the asterisk-marked (*) fields like Parts Needed By and Quantity (ea).
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5950-01-345-5596 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013455596 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| DT2747 | 5 | 2 | 5 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 10.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 110.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 12.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| ABKW | OVERALL HEIGHT | 3.875 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 100.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 200.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 300.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 1900.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY AND 230 |
| FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS 5 SECONDARY WINDINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | 27 TURRET |
| ABTB | MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL SINGLE GROUP |
| AXGY | MOUNTING METHOD | SLOT SINGLE GROUP OR UNTHREADED HOLE SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| ABHP | OVERALL LENGTH | 4.625 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 4.000 INCHES MAXIMUM |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CWJS | WINDING OPERATING VOLTAGE | 200.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
![]() |